Re: [PATCH v2 1/2] PCI: Disable D3cold on Asus B1400 PCI-NVMe bridge

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Daniel Drake <drake@xxxxxxxxxxxxx> 於 2024年2月7日 週三 下午4:44寫道:
>
> The Asus B1400 with original shipped firmware versions and VMD disabled
> cannot resume from suspend: the NVMe device becomes unresponsive and
> inaccessible.
>
> This is because the NVMe device and parent PCI bridge get put into D3cold
> during suspend, and this PCI bridge cannot be recovered from D3cold mode:
>
>   echo "0000:01:00.0" > /sys/bus/pci/drivers/nvme/unbind
>   echo "0000:00:06.0" > /sys/bus/pci/drivers/pcieport/unbind
>   setpci -s 00:06.0 CAP_PM+4.b=03 # D3hot
>   acpidbg -b "execute \_SB.PC00.PEG0.PXP._OFF"
>   acpidbg -b "execute \_SB.PC00.PEG0.PXP._ON"
>   setpci -s 00:06.0 CAP_PM+4.b=0 # D0
>   echo "0000:00:06.0" > /sys/bus/pci/drivers/pcieport/bind
>   echo "0000:01:00.0" > /sys/bus/pci/drivers/nvme/bind
>   # NVMe probe fails here with -ENODEV
>
> This appears to be an untested D3cold transition by the vendor; Intel
> socwatch shows that Windows leaves the NVMe device and parent bridge in D0
> during suspend, even though these firmware versions have StorageD3Enable=1.
>
> Experimenting with the DSDT, the _OFF method calls DL23() which sets a L23E
> bit at offset 0xe2 into the PCI configuration space for this root port.
> This is the specific write that the _ON routine is unable to recover from.
> This register is not documented in the public chipset datasheet.
>
> Disallow D3cold on the PCI bridge to enable successful suspend/resume.
>
> Link: https://bugzilla.kernel.org/show_bug.cgi?id=215742
> Signed-off-by: Daniel Drake <drake@xxxxxxxxxxxxx>

Signed-off-by: Jian-Hong Pan <jhp@xxxxxxxxxxxxx>

> ---
>  arch/x86/pci/fixup.c | 45 ++++++++++++++++++++++++++++++++++++++++++++
>  1 file changed, 45 insertions(+)
>
> v2:
> Match only specific BIOS versions where this quirk is required.
> Add subsequent patch to this series to revert the original S3 workaround
> now that s2idle is usable again.
>
> diff --git a/arch/x86/pci/fixup.c b/arch/x86/pci/fixup.c
> index f347c20247d30..6b0b341178e4f 100644
> --- a/arch/x86/pci/fixup.c
> +++ b/arch/x86/pci/fixup.c
> @@ -907,6 +907,51 @@ static void chromeos_fixup_apl_pci_l1ss_capability(struct pci_dev *dev)
>  DECLARE_PCI_FIXUP_FINAL(PCI_VENDOR_ID_INTEL, 0x5ad6, chromeos_save_apl_pci_l1ss_capability);
>  DECLARE_PCI_FIXUP_RESUME(PCI_VENDOR_ID_INTEL, 0x5ad6, chromeos_fixup_apl_pci_l1ss_capability);
>
> +/*
> + * Disable D3cold on Asus B1400 PCIe bridge at 00:06.0.
> + *
> + * On this platform with VMD off, the NVMe's parent PCI bridge cannot
> + * successfully power back on from D3cold, resulting in unresponsive NVMe on
> + * resume. This appears to be an untested transition by the vendor: Windows
> + * leaves the NVMe and parent bridge in D0 during suspend.
> + * This is only needed on BIOS versions before 308; the newer versions flip
> + * StorageD3Enable from 1 to 0.
> + */
> +static const struct dmi_system_id asus_nvme_broken_d3cold_table[] = {
> +       {
> +               .matches = {
> +                               DMI_MATCH(DMI_SYS_VENDOR, "ASUSTeK COMPUTER INC."),
> +                               DMI_MATCH(DMI_BIOS_VERSION, "B1400CEAE.304"),
> +               },
> +       },
> +       {
> +               .matches = {
> +                               DMI_MATCH(DMI_SYS_VENDOR, "ASUSTeK COMPUTER INC."),
> +                               DMI_MATCH(DMI_BIOS_VERSION, "B1400CEAE.305"),
> +               },
> +       },
> +       {
> +               .matches = {
> +                               DMI_MATCH(DMI_SYS_VENDOR, "ASUSTeK COMPUTER INC."),
> +                               DMI_MATCH(DMI_BIOS_VERSION, "B1400CEAE.306"),
> +               },
> +       },
> +       {
> +               .matches = {
> +                               DMI_MATCH(DMI_SYS_VENDOR, "ASUSTeK COMPUTER INC."),
> +                               DMI_MATCH(DMI_BIOS_VERSION, "B1400CEAE.307"),
> +               },
> +       },
> +       {}
> +};
> +
> +static void asus_disable_nvme_d3cold(struct pci_dev *pdev)
> +{
> +       if (dmi_check_system(asus_nvme_broken_d3cold_table) > 0)
> +               pci_d3cold_disable(pdev);
> +}
> +DECLARE_PCI_FIXUP_FINAL(PCI_VENDOR_ID_INTEL, 0x9a09, asus_disable_nvme_d3cold);
> +
>  #ifdef CONFIG_SUSPEND
>  /*
>   * Root Ports on some AMD SoCs advertise PME_Support for D3hot and D3cold, but
> --
> 2.43.0
>





[Index of Archives]     [Linux IBM ACPI]     [Linux Power Management]     [Linux Kernel]     [Linux Laptop]     [Kernel Newbies]     [Share Photos]     [Security]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Samba]     [Video 4 Linux]     [Device Mapper]     [Linux Resources]