Re: [PATCH v2 20/21] cxl: Export sysfs attributes for memory device QTG ID

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 





On 3/29/23 2:55 PM, Dan Williams wrote:
Dave Jiang wrote:
Export qtg_id sysfs attributes for the CXL memory device. The QTG ID
should show up as /sys/bus/cxl/devices/memX/qtg_id. The QTG ID is
retrieved via _DSM after supplying the caluclated bandwidth and latency
for the entire CXL path from device to the CPU. This ID is used to match
up to the root decoder QTG ID to determine which CFMWS the memory range
of a hotplugged CXL mem device should be assigned under.

While there may be multiple DSMAS exported by the device CDAT, the driver
will only expose the first QTG ID in sysfs for now. In the future when
multiple QTG IDs are necessary, they can be exposed. [1]

[1]: https://lore.kernel.org/linux-cxl/167571650007.587790.10040913293130712882.stgit@djiang5-mobl3.local/T/#md2a47b1ead3e1ba08f50eab29a4af1aed1d215ab

Suggested-by: Dan Williams <dan.j.williams@xxxxxxxxx>
Signed-off-by: Dave Jiang <dave.jiang@xxxxxxxxx>
---
  Documentation/ABI/testing/sysfs-bus-cxl |   11 +++++++++++
  drivers/cxl/core/memdev.c               |   15 +++++++++++++++
  2 files changed, 26 insertions(+)

diff --git a/Documentation/ABI/testing/sysfs-bus-cxl b/Documentation/ABI/testing/sysfs-bus-cxl
index 471ac9a37078..a018f0a21aca 100644
--- a/Documentation/ABI/testing/sysfs-bus-cxl
+++ b/Documentation/ABI/testing/sysfs-bus-cxl
@@ -58,6 +58,17 @@ Description:
  		affinity for this device.
+What: /sys/bus/cxl/devices/memX/qtg_id

Oh, I was still thinking there would be a qtg_id per partition type,
just not a multiple qtg_ids per partition type until it is clear that
those are something hardware vendors are actually going to ship, but I
expect a DSMAS per partition type will be common.

Oh ok. I guess I really need to save previous changes. Time to revert. I hope I still have the old cxl cli changes as well. :(


So I was expecting:

/sys/bus/cxl/devices/memX/{ram,pmem}/qtg_id

...and when the DCD patches land that expands to:

/sys/bus/cxl/devices/memX/{ram,pmem,dcd[0-7]}/qtg_id

If someone builds a device with multiple performance classes per
partition then it would become:

/sys/bus/cxl/devices/memX/{ram,pmem,dcd[0-7]}/qtg_id
/sys/bus/cxl/devices/memX/{ram,pmem,dcd[0-7]}/qtg_id[1..n]
/sys/bus/cxl/devices/memX/{ram,pmem,dcd[0-7]}/qtg_range/
/sys/bus/cxl/devices/memX/{ram,pmem,dcd[0-7]}/qtg_range[1..n]/

...where I am using CXL 3.0 Figure 9-24 "DCD DPA Space Example" as the
delineation of the possible partition types.



[Index of Archives]     [Linux IBM ACPI]     [Linux Power Management]     [Linux Kernel]     [Linux Laptop]     [Kernel Newbies]     [Share Photos]     [Security]     [Netfilter]     [Bugtraq]     [Yosemite News]     [MIPS Linux]     [ARM Linux]     [Linux Security]     [Linux RAID]     [Samba]     [Video 4 Linux]     [Device Mapper]     [Linux Resources]