On 06/01/2021 15:17, Chris Wilson wrote:
Quoting Tvrtko Ursulin (2021-01-06 15:10:02)
On 06/01/2021 12:39, Chris Wilson wrote:
AFter detecting a register mismatch between the protocontext and the
image generated by HW, immediately break out of the double loop.
(Otherwise we end up a second configuing error message.)
s/configuing/confusing/?
No use of dumping all differences? Why it is confusing?
rcs0: Different registers found at dword 2, expected 2244, found 2244
rcs0: Expected LRI command at dword 2, found 00002244
We then hexdump the entire page, both HW/SW, so we can try and figure out
what went wrong.
Right, I see it now.
Reviewed-by: Tvrtko Ursulin <tvrtko.ursulin@xxxxxxxxx>
Regards,
Tvrtko
_______________________________________________
Intel-gfx mailing list
Intel-gfx@xxxxxxxxxxxxxxxxxxxxx
https://lists.freedesktop.org/mailman/listinfo/intel-gfx