Commit '3cf71bc9904d ("drm/i915: Re-apply "Perform link quality check, unconditionally during long pulse"")' applies a work around for sinks that don't signal link loss. The work around does not need to have to be that broad as the issue was seen with only one particular monitor; limit this only for external displays as eDP features like PSR turn off the link and the driver ends up retraining the link seeeing that link is not synchronized. Cc: Lyude Paul <lyude@xxxxxxxxxx> Cc: Jan-Marek Glogowski <glogow@xxxxxxxxxx> Cc: Ville Syrjälä <ville.syrjala@xxxxxxxxxxxxxxx> Cc: Rodrigo Vivi <rodrigo.vivi@xxxxxxxxx> References: 3cf71bc9904d ("drm/i915: Re-apply "Perform link quality check, unconditionally during long pulse"") Signed-off-by: Dhinakaran Pandiyan <dhinakaran.pandiyan@xxxxxxxxx> Reviewed-by: Ville Syrjälä <ville.syrjala@xxxxxxxxxxxxxxx> --- drivers/gpu/drm/i915/intel_dp.c | 13 +++++++------ 1 file changed, 7 insertions(+), 6 deletions(-) diff --git a/drivers/gpu/drm/i915/intel_dp.c b/drivers/gpu/drm/i915/intel_dp.c index 34c561011e7a..6130d05d8b88 100644 --- a/drivers/gpu/drm/i915/intel_dp.c +++ b/drivers/gpu/drm/i915/intel_dp.c @@ -5072,12 +5072,13 @@ intel_dp_long_pulse(struct intel_connector *connector, */ status = connector_status_disconnected; goto out; - } else { - /* - * Some external monitors do not signal loss of link - * synchronization with an IRQ_HPD, so force a link status - * check. - */ + } + + /* + * Some external monitors do not signal loss of link synchronization + * with an IRQ_HPD, so force a link status check. + */ + if (!intel_dp_is_edp(intel_dp)) { struct intel_encoder *encoder = &dp_to_dig_port(intel_dp)->base; intel_dp_retrain_link(encoder, ctx); -- 2.17.1 _______________________________________________ Intel-gfx mailing list Intel-gfx@xxxxxxxxxxxxxxxxxxxxx https://lists.freedesktop.org/mailman/listinfo/intel-gfx