Quoting Daniel Vetter (2017-11-28 10:08:56) > On Tue, Nov 28, 2017 at 11:06 AM, Chris Wilson <chris@xxxxxxxxxxxxxxxxxx> wrote: > > Quoting Joonas Lahtinen (2017-11-28 08:15:13) > >> On Mon, 2017-11-27 at 16:54 +0200, Arkadiusz Hiler wrote: > >> > Hey all, > >> > > >> > For some time already CI sends out 1-2 mails per series per (re)run, i.e. BAT > >> > results and "full IGT" results (if BAT has not failed). > >> > > >> > Recently we have added 32bit build check, and if that fails it sends out > >> > additional mail In-Reply-To the series. > >> > > >> > I am working on adding some static checks to the CI (spare and checkpatch at the > >> > moment, more may come in the future), which may generate even more commotion on > >> > the mailing list. > >> > > >> > How much of CI noise is too much and how you would like to have the results > >> > grouped? > >> > > >> > Couple of options to start the discussion: > >> > > >> > 1. Group all static checks (and the 32bit build?) into one mail: > >> > - just one additional mail, > >> > - may be hard to read in case of catastrophic failure, > >> > - we can send it only when something actually fails. > >> > > >> > 2. Send out the results as a part of BAT results: > >> > - even less noise than (1), > >> > - BAT results already feel cluttered, this may decrease readability. > >> > > >> > 3. Have each check as a separate mail, but send it only if the check fails: > >> > - noisy: may result in many mails, depending how many checks fail, > >> > - easier to read and easier to follow on patchwork. > >> > >> The best user experience I could think of; > >> > >> 1. If all CI checks succeed, delay and only send one mail with all the > >> results. This would indicate it's good to merge, go do it. > >> 2. When a CI checks fail, immediately send that out so the developer > >> gets to work on the fix. > >> > >> Above requires that all the checks complete rather quickly and a trust > >> is gained to the system so that the absence of e-mail always means the > >> series is doing good, not that the system is clogged in some way :) > > > > Or just 2. The first being the compilation report; saying we > > have received your patch and it compiles fine, it will be queued to the > > farm currently in slot N (or it doesn't even compile!). The second being > > the success or failure of the CI run. > > > > From the user pov, we can't do anything until the CI report so > > intermediate emails saying congrats are just fluff. Useful simply to > > know the patch hasn't fall out of the system, but not supplying any > > actionable information. > > BAT was meant to be that mail, with the added benefit that if a series > fails the basic sanity check you can ignore it for review and > everything. Still not quite there yet (and the recently undone change > of ratelimiting didn't help). The compile check should take 30s(?) on the build host with all the distcc/ccache. It's going to be rare to develop a long queue and significant latency; whereas one developer can flood the system with 5 different series they happen to have queued, repeat for everyone getting to work in the morning. -Chris _______________________________________________ Intel-gfx mailing list Intel-gfx@xxxxxxxxxxxxxxxxxxxxx https://lists.freedesktop.org/mailman/listinfo/intel-gfx