Re: [PATCH i-g-t v3 4/4] chamelium: Dump obtained and reference frames to png on crc error

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



On 10/07/17 17:11, Paul Kocialkowski wrote:
On Mon, 2017-07-10 at 16:56 +0300, Martin Peres wrote:
On 10/07/17 15:06, Paul Kocialkowski wrote:
On Mon, 2017-07-10 at 13:33 +0300, Martin Peres wrote:
On 10/07/17 13:31, Paul Kocialkowski wrote:
On Thu, 2017-07-06 at 17:57 -0400, Lyude Paul wrote:

As well, one advantage we do have here from the chamelium end
is
that
you can only really be screen grabbing from one port at a
time. So
you
could actually just track stuff internally in the
igt_chamelium
API
and when a user tries to download a framedump that we've
already
downloaded, we can just hand them back a cached copy of it.

I forgot to answer this point. I think this bring way too much
overhead
and is not really necessary anyway. With the solution I proposed
in
my
previous email on this thread, the two wrapper functions (one
for
CRC,
one for analogue frame comparison) will either dump the frame
for
CRC
comparison (because it was never dumped before) or use the
provided
one
for analogue comparison, so there is no particular need to track
what
was or wasn't dumped before.

No need to track, just encode it in the filename:
$test-$subtest-error-crc-$crc.png

Just do not override existing files, and you are done :)

I suppose it would be best to have predictible filenames (so not
including the crc) to make it easier to grab the frame for an
automated
testing framework, right? >
So what about: frame-$test-$subtest-$qualifier.png, with $qualifier
being either "reference" or "dump". I don't think it's necessary to
indicate whether the error comes from crc or analogue frame testing:
this will already be contained in the subtest name.


Well, predictable is actually problematic, since automated systems
try
to reproduce issues, and your idea will lead to overriding (which is
only not a problem if the CRC is the same).

That is, unless the automated system moves the file around from the
predictable name to whatever suits it best (that may include which
run the result is part of).

In this case, I would like to see a way to add a prefix, so as we can avoid having another step to move files afterwards.


In the end, what we want is to say in the logs what are the files
(reference and dump). We'll need to agree on a format, so as an
automated system can pick it up :)

Parsing logs sound like a hackish way to do things quite honestly. Just
having a predictable name and moving the file wherever relevant seems a
lot easier on all sides.

Also, since we're making the code for frame dumping independent from
whether it comes from crc or full frame testing, it doesn't play out too
well to carry the crc result until the point of writing the png file.


I don't like the idea of not de-duplicating images. Let's say that we have 20 frames that fail, it takes 1 month to fix the issue and we have 10 runs per day, that would amount to 9.3G of redundant data (for a frame being 1.5MB), instead of 30 MB.

So, maybe we could have a compromise. Images are stored in $CRC.png and new files $prefix-frame-$test-$subtest-$qualifier are generated, containing the path to the right file. This is how we solved this issue for image comparison in ezbench. This way, we only add 4K per image instead of 1.5 MB.