Sometimes I see wrong Calling-Station-Id in CDRs. This is a correct CDR: |2010-03-03 16:14:42|983953495540|123|136|212.119.194.171|212.157.203.68|16|16|162 This is a INcorrect CDR: |2010-03-03 16:20:40|984957816610|70|188.128.41.94:25528|188.128.41.94|217.150.18.35|16|16|176 GK logs IP address:port instead of Calling-Station-Id. Here is my CDRString parameter: CDRString=|%{setup-time}|%{Dialed-Number}|%d|%{Calling-Station-Id}|%{caller-ip}|%{callee-ip}|%c|%{cause-translated}|%n Thees errors occurs periodically from different originating gateways (Cisco 1760. 2801. 2811). Is there a way to solve it? Thank you. |
------------------------------------------------------------------------------ Download Intel® Parallel Studio Eval Try the new software tools for yourself. Speed compiling, find bugs proactively, and fine-tune applications for parallel performance. See why Intel Parallel Studio got high marks during beta. http://p.sf.net/sfu/intel-sw-dev
_______________________________________________________ Posting: mailto:Openh323gk-users@xxxxxxxxxxxxxxxxxxxxx Archive: http://sourceforge.net/mailarchive/forum.php?forum_name=openh323gk-users Unsubscribe: http://lists.sourceforge.net/lists/listinfo/openh323gk-users Homepage: http://www.gnugk.org/