> Under certain circumstances the Antek EGW904A GateWay (base port when other > than default) after approximately 6 hours of operation behind a NAT box > (Draytek 2104/P/2300) starts flooding the GNUgk (till latest CVS) and the > status port shows RCF messages even after the GK has the GW registered. > > There should be a means of preventing excessive RCF messages. The TimeToLive > is 300 onthe GK and 120 on the GW. > > The said fault goes away only when the NAT box has it's power toggled.... > till another 6 hours later. > i have experiencd this racing condition on ip boxes that have multiple ports with seperate q931 numbers but in the registration they all seem to come in using the same q931 number extension. so line 1 registers, then line 2 registers and gk sends unregister to line 1 and line 2 is now registered, then next line tries to register and unregister goes to line 2. also in some cases if line 2 tries to make a call, it unregisters line 1 and call disconnects. on the ata i have made sure that each line has different h323 id and q931 number and i have not had this problem. regards ray ------------------------------------------------------- This SF.net email is sponsored by: SF.net Giveback Program. Does SourceForge.net help you be more productive? Does it help you create better code? SHARE THE LOVE, and help us help YOU! Click Here: http://sourceforge.net/donate/ _______________________________________________ List: Openh323gk-users@lists.sourceforge.net Archive: http://sourceforge.net/mailarchive/forum.php?forum_id=8549 Homepage: http://www.gnugk.org/