Re: Performance drop when upgrading from 3.8 to 6.5

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 




On 11/5/19 4:53 PM, Riccardo Murri wrote:
Is it possible for you to repeat the test by disabling ctime or increasing the inode size to a higher value say 1024?
Sure!  How do I disable ctime or increase the inode size?
Would this suffice to disable `ctime`?

     sudo gluster volume set glusterfs ctime off

Can it be done on a running cluster?  Do I need to unmount and remount
for clients to see the effect?


This is good enough.  There is no need to unmount.


Thanks,
R