Re: Performance drop when upgrading from 3.8 to 6.5

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



> > Is it possible for you to repeat the test by disabling ctime or increasing the inode size to a higher value say 1024?
>
> Sure!  How do I disable ctime or increase the inode size?

Would this suffice to disable `ctime`?

    sudo gluster volume set glusterfs ctime off

Can it be done on a running cluster?  Do I need to unmount and remount
for clients to see the effect?

Thanks,
R
________

Community Meeting Calendar:

APAC Schedule -
Every 2nd and 4th Tuesday at 11:30 AM IST
Bridge: https://bluejeans.com/118564314

NA/EMEA Schedule -
Every 1st and 3rd Tuesday at 01:00 PM EDT
Bridge: https://bluejeans.com/118564314

Gluster-users mailing list
Gluster-users@xxxxxxxxxxx
https://lists.gluster.org/mailman/listinfo/gluster-users



[Index of Archives]     [Gluster Development]     [Linux Filesytems Development]     [Linux ARM Kernel]     [Linux ARM]     [Linux Omap]     [Fedora ARM]     [IETF Annouce]     [Bugtraq]     [Linux OMAP]     [Linux MIPS]     [eCos]     [Asterisk Internet PBX]     [Linux API]

  Powered by Linux