Hi Marek, On Sat, 26 Oct 2024 00:53:51 +0200 Marek Vasut <marex@xxxxxxx> wrote: > On 10/24/24 11:55 AM, Herve Codina wrote: > > In some cases observed during ESD tests, the TI SN65DSI83 cannot recover > > from errors by itself. A full restart of the bridge is needed in those > > cases to have the bridge output LVDS signals again. > > I have seen the bridge being flaky sometimes, do you have any more > details of what is going on when this irrecoverable error occurs ? The panel attached to the bridge goes and stays black. That's the behavior. A full reset brings the panel back displaying frames. Best regards, Hervé