Dne ponedeljek, 18. december 2023 ob 14:35:22 CET je Frank Oltmanns napisal(a): > The Allwinner A64 manual lists the following constraint for the > PLL-VIDEO0 clock: 8 <= N/M <= 25 > > Use this constraint. > > Signed-off-by: Frank Oltmanns <frank@xxxxxxxxxxxx> > --- > drivers/clk/sunxi-ng/ccu-sun50i-a64.c | 8 ++++++-- > 1 file changed, 6 insertions(+), 2 deletions(-) > > diff --git a/drivers/clk/sunxi-ng/ccu-sun50i-a64.c b/drivers/clk/sunxi-ng/ccu-sun50i-a64.c > index c034ac027d1c..75d839da446c 100644 > --- a/drivers/clk/sunxi-ng/ccu-sun50i-a64.c > +++ b/drivers/clk/sunxi-ng/ccu-sun50i-a64.c > @@ -68,7 +68,8 @@ static SUNXI_CCU_NM_WITH_SDM_GATE_LOCK(pll_audio_base_clk, "pll-audio-base", > BIT(28), /* lock */ > CLK_SET_RATE_UNGATE); > > -static SUNXI_CCU_NM_WITH_FRAC_GATE_LOCK_MIN_MAX_CLOSEST(pll_video0_clk, "pll-video0", > +static SUNXI_CCU_NM_WITH_FRAC_GATE_LOCK_MIN_MAX_FEAT_NM_RATIO(pll_video0_clk, > + "pll-video0", > "osc24M", 0x010, > 192000000, /* Minimum rate */ > 1008000000, /* Maximum rate */ > @@ -80,7 +81,10 @@ static SUNXI_CCU_NM_WITH_FRAC_GATE_LOCK_MIN_MAX_CLOSEST(pll_video0_clk, "pll-vid > 297000000, /* frac rate 1 */ > BIT(31), /* gate */ > BIT(28), /* lock */ > - CLK_SET_RATE_UNGATE); > + CLK_SET_RATE_UNGATE, > + CCU_FEATURE_FRACTIONAL | > + CCU_FEATURE_CLOSEST_RATE, Above flags are unrelated change, put them in new patch if needed. Best regards, Jernej > + 8, 25); /* min/max nm ratio */ > > static SUNXI_CCU_NM_WITH_FRAC_GATE_LOCK(pll_ve_clk, "pll-ve", > "osc24M", 0x018, > >