Hi, On Wed, 2022-04-20 at 20:23 +0800, Rex-BC Chen wrote: > On Thu, 2022-04-07 at 21:39 -0400, Nícolas F. R. A. Prado wrote: > > The configuration for mt8192 was incorrectly using the output > > formats > > from mt8173. Since the output formats for mt8192 are instead the > > same > > ones as for mt8183, which require two bus samples per pixel, the > > pixelclock and DDR edge setting were misconfigured. This made > > external > > displays unable to show the image. > > > > Fix the issue by correcting the output format for mt8192 to be the > > same > > as for mt8183, fixing the usage of external displays for mt8192. > > > > Fixes: be63f6e8601f ("drm/mediatek: dpi: Add output bus formats to > > driver data") > > Signed-off-by: Nícolas F. R. A. Prado <nfraprado@xxxxxxxxxxxxx> > > Reviewed-by: AngeloGioacchino Del Regno < > > angelogioacchino.delregno@xxxxxxxxxxxxx> > > --- > > > > Changes in v2: > > - Added Fixes tag > > > > drivers/gpu/drm/mediatek/mtk_dpi.c | 4 ++-- > > 1 file changed, 2 insertions(+), 2 deletions(-) > > > > diff --git a/drivers/gpu/drm/mediatek/mtk_dpi.c > > b/drivers/gpu/drm/mediatek/mtk_dpi.c > > index 4554e2de1430..e61cd67b978f 100644 > > --- a/drivers/gpu/drm/mediatek/mtk_dpi.c > > +++ b/drivers/gpu/drm/mediatek/mtk_dpi.c > > @@ -819,8 +819,8 @@ static const struct mtk_dpi_conf mt8192_conf = > > { > > .cal_factor = mt8183_calculate_factor, > > .reg_h_fre_con = 0xe0, > > .max_clock_khz = 150000, > > - .output_fmts = mt8173_output_fmts, > > - .num_output_fmts = ARRAY_SIZE(mt8173_output_fmts), > > + .output_fmts = mt8183_output_fmts, > > + .num_output_fmts = ARRAY_SIZE(mt8183_output_fmts), > > }; > > > > static int mtk_dpi_probe(struct platform_device *pdev) > > Reviewed-by: Rex-BC Chen <rex-bc.chen@xxxxxxxxxxxx> > > Hello CK, > > Gentle ping for this patch. > This patch is confirmed by Xinlei and Jitao. Applied to mediatek-drm-next [1]. [1] https://git.kernel.org/pub/scm/linux/kernel/git/chunkuang.hu/linux.git/log/?h=mediatek-drm-next Regards, CK > > BRs, > Rex >