On 1/13/2022 1:52 PM, Stephen Boyd wrote:
Quoting Kuogee Hsieh (2022-01-13 12:44:16)
On 1/13/2022 11:47 AM, Stephen Boyd wrote:
Quoting Kuogee Hsieh (2022-01-13 09:51:42)
On 1/12/2022 8:13 PM, Stephen Boyd wrote:
- if (dp->usbpd->orientation == ORIENTATION_CC2)
- flip = true;
+ dp_power_init(dp->power, false);
+ dp_ctrl_reset_irq_ctrl(dp->ctrl, true);
+
+ /*
+ * eDP is the embedded primary display and has its own phy
+ * initialize phy immediately
Question still stands why we can't wait for hpd high from the eDP panel.
Also, I think "has its own phy" means that it's not part of a combo
USB+DP phy? Can you please clarify?
Correct, eDP has its dedicated phy which is not part of combo phy.
Why does that mean we can't wait for hpd high from the eDP panel?
Sorry, missed this one.
Yes, it can wait for hpd high.
Since it always presented, I just think it is better to show display
sooner not later until hdp high.
you like it to wait until hpd high?
+ */
+ if (dp->dp_display.connector_type == DRM_MODE_CONNECTOR_eDP)
+ dp_display_host_phy_init(dp);
- dp_power_init(dp->power, flip);
- dp_ctrl_host_init(dp->ctrl, flip, reset);
dp_aux_init(dp->aux);
dp->core_initialized = true;
}
@@ -1306,20 +1330,23 @@ static int dp_pm_resume(struct device *dev)
dp->hpd_state = ST_DISCONNECTED;
/* turn on dp ctrl/phy */
- dp_display_host_init(dp, true);
+ dp_display_host_init(dp);
dp_catalog_ctrl_hpd_config(dp->catalog);
- /*
- * set sink to normal operation mode -- D0
- * before dpcd read
- */
- dp_link_psm_config(dp->link, &dp->panel->link_info, false);
if (dp_catalog_link_is_connected(dp->catalog)) {
+ /*
+ * set sink to normal operation mode -- D0
+ * before dpcd read
+ */
+ dp_display_host_phy_init(dp);
+ dp_link_psm_config(dp->link, &dp->panel->link_info, false);
sink_count = drm_dp_read_sink_count(dp->aux);
if (sink_count < 0)
sink_count = 0;
+
+ dp_display_host_phy_exit(dp);
Why is the phy exited on resume when the link is still connected? Is
this supposed to be done only when the sink_count is 0? And how does
this interact with eDP where the phy is initialized by the call to
dp_display_host_init() earlier in this function.
At beginning of dp_pm_resume bot core_initialized and phy_initialized
should be off.
However at the case of dongle still connected to DUT, we have to read
dongle dpcd to decided any hdmi connect to dongle (sink_count != 0). in
this case, we have to turn on phy to perform dpcd read and turn off phy
after read so the following plugged-in interrupt can be handled correctly.
That looks like a lot of wasted work. Why can't we turn on the core,
turn on the phy, check if it's connected, and then turn off the phy if
it isn't? At the least, please put a comment above this phy_exit() call
indicating that we'll turn the phy back on while processing a plugged in
interrupt.