On Tue, Dec 21, 2021 at 10:31:23AM -0400, Rob Herring wrote: > On Mon, Dec 20, 2021 at 12:06:16PM +0100, Sascha Hauer wrote: > > "vpll" is a misnomer. A clock input to a device should be named after > > the usage in the device, not after the clock that drives it. On the > > rk3568 the same clock is driven by the HPLL. > > To fix that, this patch renames the vpll clock to ref clock. > > The problem with this series is it breaks an old kernel with new dt. You > can partially mitigate that with stable kernel backport, but IMO keeping > the old name is not a burden to maintain. As suggested I only removed vpll from the binding document, but not from the code. The code still handles the old binding as well. Sascha -- Pengutronix e.K. | | Steuerwalder Str. 21 | http://www.pengutronix.de/ | 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |