Hi Paul. On Mon, Jul 27, 2020 at 06:46:08PM +0200, Paul Cercueil wrote: > Add documentation for the Device Tree node for LCD panels based on the > NewVision NV3052C controller. > > Signed-off-by: Paul Cercueil <paul@xxxxxxxxxxxxxxx> Very happy to see work on RG-350 :-) Some feedback below. Sam > --- > .../display/panel/newvision,nv3052c.yaml | 69 +++++++++++++++++++ > 1 file changed, 69 insertions(+) > create mode 100644 Documentation/devicetree/bindings/display/panel/newvision,nv3052c.yaml > > diff --git a/Documentation/devicetree/bindings/display/panel/newvision,nv3052c.yaml b/Documentation/devicetree/bindings/display/panel/newvision,nv3052c.yaml > new file mode 100644 > index 000000000000..751a28800fc2 > --- /dev/null > +++ b/Documentation/devicetree/bindings/display/panel/newvision,nv3052c.yaml > @@ -0,0 +1,69 @@ > +# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause) > +%YAML 1.2 > +--- > +$id: http://devicetree.org/schemas/display/panel/newvision,nv3052c.yaml# > +$schema: http://devicetree.org/meta-schemas/core.yaml# > + > +title: NewVision NV3052C TFT LCD panel driver with SPI control bus > + > +maintainers: > + - Paul Cercueil <paul@xxxxxxxxxxxxxxx> > + > +description: | > + This is a driver for 320x240 TFT panels, The binding describes the HW, not the driver. So please re-phrase this part. This datasheet: https://www.phoenixdisplay.com/wp-content/uploads/2019/05/NV3052C-Datasheet-V0.2.pdf tells that the driver supports additional resoltions. I guess the 320x240 resolution is limited to the leadtek panel. > + accepting a variety of input > + streams that get adapted and scaled to the panel. The panel output has > + 960 TFT source driver pins and 240 TFT gate driver pins, VCOM, VCOML and > + VCOMH outputs. > + > + The panel must obey the rules for a SPI slave device as specified in > + spi/spi-controller.yaml > + > +allOf: > + - $ref: panel-common.yaml# > + > +properties: > + compatible: > + items: > + - enum: > + - leadtek,ltk035c5444t-spi > + > + - const: newvision,nv3052c > + > + reg: > + maxItems: 1 > + > + reset-gpios: true > + port: true > + > +required: > + - compatible > + - reg > + > +unevaluatedProperties: false > + Do the panel need any power? I had expected to see a power-supply node as mandatory. > +examples: > + - | > + #include <dt-bindings/gpio/gpio.h> > + spi { > + #address-cells = <1>; > + #size-cells = <0>; > + > + display@0 { > + compatible = "leadtek,ltk035c5444t-spi", "newvision,nv3052c"; > + reg = <0>; > + > + spi-max-frequency = <15000000>; > + spi-3wire; > + reset-gpios = <&gpe 2 GPIO_ACTIVE_LOW>; > + backlight = <&backlight>; > + power-supply = <&vcc>; These would fail later due to "unevaluatedProperties: false". Add them above like backlight: true power-supply: true as done for reset-gpios for example. > + > + port { > + panel_input: endpoint { > + remote-endpoint = <&panel_output>; > + }; > + }; > + }; > + }; Personally I prefer 4 space indent. But there is no fixed rule (yet) what to use. > + > +... > -- > 2.27.0 _______________________________________________ dri-devel mailing list dri-devel@xxxxxxxxxxxxxxxxxxxxx https://lists.freedesktop.org/mailman/listinfo/dri-devel