Am Freitag, 11. Januar 2019, 15:54:24 CET schrieb Rob Herring: > On Sun, Dec 30, 2018 at 06:22:00PM +0100, Heiko Stuebner wrote: > > Hi Johan, > > > > Am Samstag, 29. Dezember 2018, 14:33:14 CET schrieb Johan Jonker: > > > From: Mark Yao <mark.yao@xxxxxxxxxxxxxx> > > > > > > This patch adds the rk3066 VOP definitions. > > > > > > The VOP or LCD Controller serves as interface between > > > framebuffer memory and a display device (LCD panel or TV set). > > > > > > This SOC has two symmetrical LCDC's for a dual panel application. > > > > > > A LCDC has 5 display layers. > > > Only 3 are used here. > > > > > > - Video layer 0 (Win0) > > > - Video layer 1 (Win1) > > > - OSD layer (Win2) > > > > Patch itself looks good, we'll need to wait a bit to give Rob a chance > > to look at the (simple) dt-binding change and I'll drop the paragraph > > about the display layers when applying. > > Don't wait on me for simple oneline compatible additions. This more or less was the fault of the year change :-D ... most of the time I'd apply a simple new compatible earlier and possibly without Ack ;-) . And I've applied the patch to drm-misc-next now (for 5.1). Heiko _______________________________________________ dri-devel mailing list dri-devel@xxxxxxxxxxxxxxxxxxxxx https://lists.freedesktop.org/mailman/listinfo/dri-devel