On 11/12/18 16:48, Jyri Sarha wrote: >> + /* Get the setup and hold time from vendor-specific properties. */ >> + of_property_read_u32(dvi->dev->of_node, "ti,deskew", (u32 *)&deskew); >> + if (deskew < -4 || deskew > 3) >> + return -EINVAL; > > Is "ti,deskew" property documented somewhere? If it is, I could not find > it. Could it be added to the tfp410 binding document, or somewhere else? Patch 2 of this series. Tomi -- Texas Instruments Finland Oy, Porkkalankatu 22, 00180 Helsinki. Y-tunnus/Business ID: 0615521-4. Kotipaikka/Domicile: Helsinki _______________________________________________ dri-devel mailing list dri-devel@xxxxxxxxxxxxxxxxxxxxx https://lists.freedesktop.org/mailman/listinfo/dri-devel