from Alex Deucher
It is implemented. power1_cap_min/max are RO. They define the range of values that are valid for power. The OEM defines the range and the information is stored in tables in the vbios. The driver uses that to set the range of valid values. My understanding is that windows does the same thing. I'll see if I can find out why you are seeing a different limit on windows.