Hi Sebastian,
Sebastian Reitenbach wrote:
Hi,
I do present 8 luns to the cluster. For each lun there are 4 ways through the
SAN that can be used. Therefore I have devices like /dev/sdaa /dev/sdab and
so on. The output of multipath -ll shows some disks with 4 paths, some with
three, some only with two. In the output of multipath -ll only disks with
three letters are shown e.g. /dev/sda.
when I run e.g. /sbin/scsi_id -g -u -s /block/sdaa, then it outputs one of the
configured ID's that I already have in /etc/multipath.conf.
How can I add these disks to the multipath failover?
I'm on SLES10 sp2.
Have you enabled udev?
No, it's not on by default. Don't ask.
Cheers,
Hannes
--
Dr. Hannes Reinecke zSeries & Storage
hare@xxxxxxx +49 911 74053 688
SUSE LINUX Products GmbH, Maxfeldstr. 5, 90409 Nürnberg
GF: Markus Rex, HRB 16746 (AG Nürnberg)
--
dm-devel mailing list
dm-devel@xxxxxxxxxx
https://www.redhat.com/mailman/listinfo/dm-devel