Hi Peng, On 20.12.24 07:18, Peng Fan wrote: > On Thu, Dec 19, 2024 at 08:27:37AM +0100, Ahmad Fatoum wrote: >> The IMX8MPCEC datasheet lists maximum frequencies allowed for different >> modules. Some of these limits are universal, but some depend on >> whether the SoC is operating in nominal or in overdrive mode. >> >> The imx8mp.dtsi currently assumes overdrive mode and configures some >> clocks in accordance with this. Boards wishing to make use of nominal >> mode will need to override some of the clock rates manually. >> >> As operating the clocks outside of their allowed range can lead to >> difficult to debug issues, it makes sense to register the maximum rates >> allowed in the driver, so the CCF can take them into account. >> >> Signed-off-by: Ahmad Fatoum <a.fatoum@xxxxxxxxxxxxxx> >> + imx8mp_clocks_apply_constraints(imx8mp_clock_common_constraints); >> + >> + if (of_property_read_bool(np, "fsl,nominal-mode")) >> + imx8mp_clocks_apply_constraints(imx8mp_clock_nominal_constraints); >> + else if (of_property_read_bool(np, "fsl,overdrive-mode")) >> + imx8mp_clocks_apply_constraints(imx8mp_clock_overdrive_constraints); > > As I replied, a boot parameter should be better? the mode is a soc level mode, > not just clock controller. I think it's counterproductive for a sanity check to be enforced via kernel command-line. The Skov board shouldn't run with overdrive frequencies and I prefer to encode that in the same device tree, where I define the permissible VDD_SOC range and configure the initial clock rates. The mode is selected by the VDD_SOC voltage, but affects AFAICS only the clock tree. IMO, the clock controller module is thus a natural place for the property. Cheers, Ahmad > > Thanks, > Peng > >> + >> err = of_clk_add_hw_provider(np, of_clk_hw_onecell_get, clk_hw_data); >> if (err < 0) { >> dev_err(dev, "failed to register hws for i.MX8MP\n"); >> >> -- >> 2.39.5 >> > -- Pengutronix e.K. | | Steuerwalder Str. 21 | http://www.pengutronix.de/ | 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |