On 06/08/2024 22:13, Vladimir Zapolskiy wrote: >> + >> + reg: >> + maxItems: 1 >> + >> + interrupts: >> + maxItems: 1 >> + >> + clocks: >> + maxItems: 1 >> + >> + clock-names: >> + const: timerclk >> + >> + resets: >> + maxItems: 1 >> + >> +required: >> + - compatible >> + - reg >> + - interrupts >> + - clocks >> + - clock-names > > Since there is always just a single supply clock, there is no need to > specify "clock-names" as a required one, please change it. ??? That's a conversion. Why do you expect changing several DTS files and maybe also driver? That's not needed for conversion. No. Best regards, Krzysztof