On 11/06/2024 00:13, Judith Mendez wrote: > > Hi Krzysztof, > > On 6/10/24 9:58 AM, Krzysztof Kozlowski wrote: >> On 10/06/2024 16:46, Judith Mendez wrote: >>> Add new compatible ti,am62-eqep for TI K3 devices. If a device >>> uses this compatible, require power-domains property. >>> >>> Since there is only one functional and interface clock for eqep, >>> clock-names is not really required, so removed from required >>> section, make it optional for ti,am3352-eqep compatible, and >>> update the example. >>> >> >> ... >> >> >>> interrupts = <79>; >>> }; >>> >>> + - | >>> + #include <dt-bindings/interrupt-controller/irq.h> >>> + #include <dt-bindings/interrupt-controller/arm-gic.h> >>> + #include <dt-bindings/soc/ti,sci_pm_domain.h> >>> + >>> + bus { >>> + #address-cells = <2>; >>> + #size-cells = <2>; >>> + eqep1: counter@23210000 { >> >> No need for label >> >>> + compatible = "ti,am62-eqep"; >>> + reg = <0x00 0x23210000 0x00 0x100>; >>> + power-domains = <&k3_pds 60 TI_SCI_PD_EXCLUSIVE>; >>> + clocks = <&k3_clks 60 0>; >>> + interrupts = <GIC_SPI 117 IRQ_TYPE_EDGE_RISING>; >>> + status = "disabled"; >> >> Drop... which also points to another comment - since this was no-op and >> example is basically the same, then just don't add it. No point. > > Ok, then I will drop the new example, thanks. > > BTW.. > In the existing example for ti,am3352-eqep compatible, > do you know if it is appropriate to drop clock-names > from the example if it is no longer required? > It does not really matter. Best regards, Krzysztof