On Tue, Feb 17, 2015 at 03:18:40PM +0100, Geert Uytterhoeven wrote: > Hi Mark, > > On Tue, Feb 17, 2015 at 3:01 PM, Mark Brown <broonie@xxxxxxxxxx> wrote: > > On Tue, Feb 17, 2015 at 01:11:12PM +0100, Geert Uytterhoeven wrote: > >> - Does there exist any regulator notifier event that corresponds to > >> DA9210_E_VMAX? > > What does that mean, I might be able to tell you? I guess it might be > > an over voltage event... > Possibly. There's no regulator notifier event for that yet, though. > Shall I add one? I'm wondering if it may be better to change the first notification to just a general "out of regulation" one, though the consequences of over voltage are usually different to under voltage if that is what's going on here. > Anyway, let's wait for confirmation from Dialog... I guess - is there really no indication in the datasheet?