Re: [PATCH v1 2/3] dt-bindings: arm: mediatek: mmsys: Add OF graph support for board path

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

 



Il 08/04/24 05:20, Chen-Yu Tsai ha scritto:
On Thu, Apr 4, 2024 at 4:16 PM AngeloGioacchino Del Regno
<angelogioacchino.delregno@xxxxxxxxxxxxx> wrote:

Document OF graph on MMSYS/VDOSYS: this supports up to three DDP paths
per HW instance (so potentially up to six displays for multi-vdo SoCs).

The MMSYS or VDOSYS is always the first component in the DDP pipeline,
so it only supports an output port with multiple endpoints - where each
endpoint defines the starting point for one of the (currently three)
possible hardware paths.

Signed-off-by: AngeloGioacchino Del Regno <angelogioacchino.delregno@xxxxxxxxxxxxx>
---
  .../bindings/arm/mediatek/mediatek,mmsys.yaml | 23 +++++++++++++++++++
  1 file changed, 23 insertions(+)

diff --git a/Documentation/devicetree/bindings/arm/mediatek/mediatek,mmsys.yaml b/Documentation/devicetree/bindings/arm/mediatek/mediatek,mmsys.yaml
index b3c6888c1457..90758bb5bcb1 100644
--- a/Documentation/devicetree/bindings/arm/mediatek/mediatek,mmsys.yaml
+++ b/Documentation/devicetree/bindings/arm/mediatek/mediatek,mmsys.yaml
@@ -93,6 +93,29 @@ properties:
    '#reset-cells':
      const: 1

+  port:
+    $ref: /schemas/graph.yaml#/properties/port
+    description:
+      Output port node. This port connects the MMSYS/VDOSYS output to
+      the first component of one display pipeline, for example one of
+      the available OVL or RDMA blocks.
+      Some MediaTek SoCs support up to three display outputs per MMSYS.
+    properties:
+      endpoint@0:
+        $ref: /schemas/graph.yaml#/properties/endpoint
+        description: Output to the primary display pipeline
+
+      endpoint@1:
+        $ref: /schemas/graph.yaml#/properties/endpoint
+        description: Output to the secondary display pipeline
+
+      endpoint@2:
+        $ref: /schemas/graph.yaml#/properties/endpoint
+        description: Output to the tertiary display pipeline
+
+      required:
+        - endpoint@0
+

Technically the mmsys device serves as an glue layer for the display
pipeline, providing things like clock control and signal routing; the
device itself is not part of the pipeline, and probably shouldn't be
part of the graph?


That is (only) partially true: in the case of older SoCs, the MMSYS can only
connect to a single first IP of the pipeline, but in the case of newer ones,
and especially (but not limited to) MT8195 onwards having multiple instances
of VDOSYS, that really becomes part of the pipeline.

This is not because of the possible different first IP in the pipeline, but
because of support for dual-interface (DSI and DP) that, in even newer SoCs,
can be done with cross-mmsys (cross-vdosys, actually...) as some of those do
have the two in different VDOs.

So yes, this can be done without the graph in MMSYS *in this precise moment in
time*, but we'll anyway end up adding it sooner than later - and I'm doing this
right now, instead of later, because it's also simplifying the implementation
so like that I'm "catching two birds with one stone" :-)

Cheers,
Angelo

ChenYu

  required:
    - compatible
    - reg
--
2.44.0







[Index of Archives]     [Device Tree Compilter]     [Device Tree Spec]     [Linux Driver Backports]     [Video for Linux]     [Linux USB Devel]     [Linux PCI Devel]     [Linux Audio Users]     [Linux Kernel]     [Linux SCSI]     [XFree86]     [Yosemite Backpacking]


  Powered by Linux