Quoting Chen Wang (2024-02-19 19:08:59) > +required: > + - compatible > + - reg > + - clocks > + - '#clock-cells' > + > +additionalProperties: false > + > +examples: > + - | > + clock-controller@10000000 { This is the same address as the pll binding before this. How does that work? It's the same register area as the pll node. The resulting DTB should only have one compatible for this node. > + compatible = "sophgo,sg2042-rpgate"; > + reg = <0x10000000 0x10000>; > + clocks = <&clkgen 85>; > + #clock-cells = <1>; > + };