Add device tree bindings for MLX90635 Infra Red contactless temperature sensor. Signed-off-by: Crt Mori <cmo@xxxxxxxxxxx> Reviewed-by: Rob Herring <robh@xxxxxxxxxx> --- .../iio/temperature/melexis,mlx90632.yaml | 19 +++++++++++++++++-- 1 file changed, 17 insertions(+), 2 deletions(-) diff --git a/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml b/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml index 4a55e7f25ae7..03bb5d4fa8b5 100644 --- a/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml +++ b/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml @@ -4,7 +4,7 @@ $id: http://devicetree.org/schemas/iio/temperature/melexis,mlx90632.yaml# $schema: http://devicetree.org/meta-schemas/core.yaml# -title: Melexis MLX90632 contactless Infra Red temperature sensor +title: Melexis MLX90632 and MLX90635 contactless Infra Red temperature sensor maintainers: - Crt Mori <cmo@xxxxxxxxxxx> @@ -27,9 +27,24 @@ description: | Since measured object emissivity effects Infra Red energy emitted, emissivity should be set before requesting the object temperature. + https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90635 + + MLX90635 is most suitable for consumer applications where + measured object temperature is in range between -20 to 100 degrees + Celsius with relative error of measurement 2 degree Celsius in + object temperature range for industrial applications, while just 0.2 + degree Celsius for human body measurement applications. Since it can + operate and measure ambient temperature in range of -20 to 85 degrees + Celsius it is suitable also for outdoor use. + + Since measured object emissivity effects Infra Red energy emitted, + emissivity should be set before requesting the object temperature. + properties: compatible: - const: melexis,mlx90632 + enum: + - melexis,mlx90632 + - melexis,mlx90635 reg: maxItems: 1 -- 2.40.1