On Wed, 29 Nov 2023 09:30:23 +0100 Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx> wrote: > On 28/11/2023 22:48, Rob Herring wrote: > > The example for the TI Palmas ADC is incomplete as the binding is the > > full PMIC, not just the sub-functions. It is preferred for MFD examples > > to be complete in the top-level MFD device binding rather than piecemeal > > in each sub-function binding. > > > > This also fixes an undocumented (by schema) compatible warning for > > '"ti,twl6035-pmic", "ti,palmas-pmic"'. > > > > Signed-off-by: Rob Herring <robh@xxxxxxxxxx> > > --- > > Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx> > > Best regards, > Krzysztof > Applied to the togreg branch of iio.git and pushed out as testing for all the normal reasons. Thanks, Jonathan