On Mon, Jan 05, 2015 at 08:30:05AM -0500, Tejun Heo wrote: > On Mon, Jan 05, 2015 at 03:51:45PM +0530, Suman Tripathi wrote: > > Due to H/W errata, the controller is unable to save the PMP > > field fetched from command header before sending the H2D FIS. > > When the device returns the PMP port field in the D2H FIS, there is > > a mismatch and results in command completion failure. The workaround > > is to write the pmp value to PxFBS.DEV field before issuing any command > > to PMP. > > > > Signed-off-by: Suman Tripathi <stripathi@xxxxxxx> > > Applied 1-2 to libata/for-3.20. Reverted due to conflicts with the endian fix patches. Please rebase these two on top of them. Thanks. -- tejun -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html