On Tue, Sep 19, 2023 at 11:45:22PM +0300, Gokhan Celik wrote: > +required: > + - compatible > + - reg > + - regulator-min-microvolt > + - regulator-max-microvolt There should not normally be a requirement to specify voltage constraints, it should be valid for the system to not permit any configuration of the voltage at runtime and just use whatever state it was left with when the kernel was started (eg, hardware or bootloader default).