Add power supply regulator support to the exc3000 devices. Signed-off-by: Mike Looijmans <mike.looijmans@xxxxxxxx> --- drivers/input/touchscreen/exc3000.c | 7 +++++++ 1 file changed, 7 insertions(+) diff --git a/drivers/input/touchscreen/exc3000.c b/drivers/input/touchscreen/exc3000.c index 4af4c1e5d0da..3e50af8a4a2d 100644 --- a/drivers/input/touchscreen/exc3000.c +++ b/drivers/input/touchscreen/exc3000.c @@ -18,6 +18,7 @@ #include <linux/interrupt.h> #include <linux/module.h> #include <linux/of.h> +#include <linux/regulator/consumer.h> #include <linux/sizes.h> #include <linux/timer.h> #include <asm/unaligned.h> @@ -360,6 +361,12 @@ static int exc3000_probe(struct i2c_client *client) if (IS_ERR(data->reset)) return PTR_ERR(data->reset); + /* For proper reset sequence, enable power while reset asserted */ + error = devm_regulator_get_enable_optional(&client->dev, "vdd"); + if (error && error != -ENODEV) + dev_err_probe(&client->dev, error, + "failed to request vdd regulator\n"); + if (data->reset) { msleep(EXC3000_RESET_MS); gpiod_set_value_cansleep(data->reset, 0); -- 2.17.1 Met vriendelijke groet / kind regards, Mike Looijmans System Expert TOPIC Embedded Products B.V. Materiaalweg 4, 5681 RJ Best The Netherlands T: +31 (0) 499 33 69 69 E: mike.looijmans@xxxxxxxxxxxxxxxxx W: www.topic.nl Please consider the environment before printing this e-mail