On Fri, Feb 10, 2023 at 12:05 AM <matthias.bgg@xxxxxxxxxx> wrote: > > From: Matthias Brugger <matthias.bgg@xxxxxxxxx> > > This reverts commit fc6634ac0e5380aeb1063275a2e9a583d41b2306. > > The mmsys is a clock provider but does not have any clocks connected to > it. Therefore assigned-clock properties should be applied to the users of mmsys. If there are multiple users that need this, then it should be moved to the clock provider node topckgen. > This fixes the DT schema check: > mediatek/mt8173-elm.dtb: syscon@14000000: 'assigned-clock-rates', 'assigned-clocks' do not match any of the regexes: 'pinctrl-[0-9]+' > > Signed-off-by: Matthias Brugger <matthias.bgg@xxxxxxxxx> > --- > > arch/arm64/boot/dts/mediatek/mt8173.dtsi | 2 -- > 1 file changed, 2 deletions(-) > > diff --git a/arch/arm64/boot/dts/mediatek/mt8173.dtsi b/arch/arm64/boot/dts/mediatek/mt8173.dtsi > index c47d7d900f283..b753547e250fe 100644 > --- a/arch/arm64/boot/dts/mediatek/mt8173.dtsi > +++ b/arch/arm64/boot/dts/mediatek/mt8173.dtsi > @@ -988,8 +988,6 @@ mmsys: syscon@14000000 { > compatible = "mediatek,mt8173-mmsys", "syscon"; > reg = <0 0x14000000 0 0x1000>; > power-domains = <&spm MT8173_POWER_DOMAIN_MM>; > - assigned-clocks = <&topckgen CLK_TOP_MM_SEL>; > - assigned-clock-rates = <400000000>; > #clock-cells = <1>; > #reset-cells = <1>; > mboxes = <&gce 0 CMDQ_THR_PRIO_HIGHEST>, > -- > 2.39.0 > >