From: Matthias Brugger <matthias.bgg@xxxxxxxxx> This reverts commit fc6634ac0e5380aeb1063275a2e9a583d41b2306. The mmsys is a clock provider but does not have any clocks connected to it. Therefore assigned-clock properties should be applied to the users of mmsys. This fixes the DT schema check: mediatek/mt8173-elm.dtb: syscon@14000000: 'assigned-clock-rates', 'assigned-clocks' do not match any of the regexes: 'pinctrl-[0-9]+' Signed-off-by: Matthias Brugger <matthias.bgg@xxxxxxxxx> --- arch/arm64/boot/dts/mediatek/mt8173.dtsi | 2 -- 1 file changed, 2 deletions(-) diff --git a/arch/arm64/boot/dts/mediatek/mt8173.dtsi b/arch/arm64/boot/dts/mediatek/mt8173.dtsi index c47d7d900f283..b753547e250fe 100644 --- a/arch/arm64/boot/dts/mediatek/mt8173.dtsi +++ b/arch/arm64/boot/dts/mediatek/mt8173.dtsi @@ -988,8 +988,6 @@ mmsys: syscon@14000000 { compatible = "mediatek,mt8173-mmsys", "syscon"; reg = <0 0x14000000 0 0x1000>; power-domains = <&spm MT8173_POWER_DOMAIN_MM>; - assigned-clocks = <&topckgen CLK_TOP_MM_SEL>; - assigned-clock-rates = <400000000>; #clock-cells = <1>; #reset-cells = <1>; mboxes = <&gce 0 CMDQ_THR_PRIO_HIGHEST>, -- 2.39.0