On Mon, Jan 16, 2023 at 09:01:08AM +0800, Peng Fan wrote: > Hi Oleksij, > > On 1/13/2023 10:27 PM, Oleksij Rempel wrote: > > Old imx6q machine code makes RGMII/RMII clock direction decision based on > > configuration of "ptp" clock. "enet_out" is not used and make no real > > sense, since we can't configure it as output or use it as clock > > provider. > > > > Instead of "enet_out" use "enet_clk_ref" which is actual selector to > > choose between internal and external clock source: > > > > FEC MAC <---------- enet_clk_ref <--------- SoC PLL > > \ > > ^------<-> refclock PAD (bi directional) > > > > Signed-off-by: Oleksij Rempel <o.rempel@xxxxxxxxxxxxxx> > > --- > > arch/arm/boot/dts/imx6qdl.dtsi | 4 ++-- > > 1 file changed, 2 insertions(+), 2 deletions(-) > > > > diff --git a/arch/arm/boot/dts/imx6qdl.dtsi b/arch/arm/boot/dts/imx6qdl.dtsi > > index ff1e0173b39b..71522263031a 100644 > > --- a/arch/arm/boot/dts/imx6qdl.dtsi > > +++ b/arch/arm/boot/dts/imx6qdl.dtsi > > @@ -1050,8 +1050,8 @@ fec: ethernet@2188000 { > > clocks = <&clks IMX6QDL_CLK_ENET>, > > <&clks IMX6QDL_CLK_ENET>, > > <&clks IMX6QDL_CLK_ENET_REF>, > > - <&clks IMX6QDL_CLK_ENET_REF>; > > - clock-names = "ipg", "ahb", "ptp", "enet_out"; > > + <&clks IMX6QDL_CLK_ENET_REF_SEL>; > > + clock-names = "ipg", "ahb", "ptp", "enet_clk_ref"; > > > Please also update fec binding, otherwise there will be dtbs check error. Hm, there is no restriction on enet_clk_ref use or requirements to use enet_out in Documentation/devicetree/bindings/net/fsl,fec.yaml Do I missing something? Regards, Oleksij -- Pengutronix e.K. | | Steuerwalder Str. 21 | http://www.pengutronix.de/ | 31137 Hildesheim, Germany | Phone: +49-5121-206917-0 | Amtsgericht Hildesheim, HRA 2686 | Fax: +49-5121-206917-5555 |