On 12/19/22 09:57, Krzysztof Kozlowski wrote:
On 19/12/2022 09:46, Marek Vasut wrote:
if does not match on 6q/6sx/7d/23-apbx/28-abbh/28-apbx then 8
if does not match on 6q/6sx/7d/23-apbh then 16
But if there is a better way to validate the above, please do tell.
Then your existing if:then: is also not correct because you require for
fsl,imx28-dma-apbh (as it is not in second if:then:) const:16. Just
don't require it.
So, shall I just drop the entire allOf: section ?
No, what about the interrupts?
The interrupts and dma-channels are matched 1:1 for this controller, 1
DMA channel, 1 interrupt. 16 dma channels means 16 interrupts .
Ah, then probably you need to drop entire allOf,.
Oh well ... too bad.