Allow specifying the exact calibration mode and calibration data as nvmem cells, rather than specifying just a single calibration data blob. Acked-by: Krzysztof Kozlowski <krzysztof.kozlowski@xxxxxxxxxx> Reviewed-by: Amit Kucheria <amitk@xxxxxxxxxx> Signed-off-by: Dmitry Baryshkov <dmitry.baryshkov@xxxxxxxxxx> --- .../bindings/thermal/qcom-tsens.yaml | 64 ++++++++++++++++--- 1 file changed, 54 insertions(+), 10 deletions(-) diff --git a/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml b/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml index 1a5928cce133..f14713fd3a99 100644 --- a/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml +++ b/Documentation/devicetree/bindings/thermal/qcom-tsens.yaml @@ -78,18 +78,62 @@ properties: - const: critical nvmem-cells: - minItems: 1 - maxItems: 2 - description: - Reference to an nvmem node for the calibration data + oneOf: + - minItems: 1 + maxItems: 2 + description: + Reference to an nvmem node for the calibration data + - minItems: 5 + maxItems: 35 + description: | + Reference to nvmem cells for the calibration mode, two calibration + bases and two cells per each sensor nvmem-cell-names: - minItems: 1 - items: - - const: calib - - enum: - - calib_backup - - calib_sel + oneOf: + - minItems: 1 + items: + - const: calib + - enum: + - calib_backup + - calib_sel + - minItems: 5 + items: + - const: mode + - const: base1 + - const: base2 + - const: s0_p1 + - const: s0_p2 + - const: s1_p1 + - const: s1_p2 + - const: s2_p1 + - const: s2_p2 + - const: s3_p1 + - const: s3_p2 + - const: s4_p1 + - const: s4_p2 + - const: s5_p1 + - const: s5_p2 + - const: s6_p1 + - const: s6_p2 + - const: s7_p1 + - const: s7_p2 + - const: s8_p1 + - const: s8_p2 + - const: s9_p1 + - const: s9_p2 + - const: s10_p1 + - const: s10_p2 + - const: s11_p1 + - const: s11_p2 + - const: s12_p1 + - const: s12_p2 + - const: s13_p1 + - const: s13_p2 + - const: s14_p1 + - const: s14_p2 + - const: s15_p1 + - const: s15_p2 "#qcom,sensors": description: -- 2.35.1