On Thu, Nov 03, 2022 at 03:12:32PM +0100, Marek Szyprowski wrote: > Force controlling of the generic USB PHYs also from XHCI HCD to let XHCI > driver call calibrate() method during the HCD reset. DWC3 also controls > USB PHYs, but it is not able to call the calibrate() method at the right > moment. > > Fixes: 6000b8d900cd ("usb: dwc3: disable USB core PHY management") > Reported-by: Stefan Agner <stefan@xxxxxxxx> > Signed-off-by: Marek Szyprowski <m.szyprowski@xxxxxxxxxxx> > --- > This fixes the issue reported here: > https://lore.kernel.org/all/808bdba846bb60456adf10a3016911ee@xxxxxxxx/ > > Alternative for this change is a complete revert of the 6000b8d900cd > ("usb: dwc3: disable USB core PHY management") commit. We can revert that commit if something is broken so it can be fixed properly instead of this. thanks, greg k-h