On Tue, Oct 25, 2022 at 4:16 AM Naresh Solanki <naresh.solanki@xxxxxxxxxxxxx> wrote: > > > > On 24-10-2022 09:48 pm, Rob Herring wrote: > > So if we unload and reload the driver module, it should go back to the > > default? > This is RPM to be set during probe if desired. > > > > I think it is really, 'target RPM if not already configured' which could > > be keep the setting from a register (e.g. what the bootloader set) or > > perhaps you already have temperature information to use... > Yes. missed it. It should be target-rpm will correct this. in next version. > > > >> + $ref: /schemas/types.yaml#/definitions/uint32 > >> + pwm-frequency: > >> + description: > >> + PWM frequency for fan in Hertz(Hz). > >> + $ref: /schemas/types.yaml#/definitions/uint32 > >> + > >> + pwm-polarity-inverse: > >> + description: > >> + Inverse PWM polarity for fan. > >> + type: boolean > > As I said before, the PWM binding handles these 2 settings. Use it. Yes, > > it's a bit of an overkill when the child is the consumer of the parent. > > Until some 'clever' h/w engineer decides to use one of the PWMs for > > something else like a backlight. > I would like you to consider this as something recommended by fan > datasheet for the given fan instance. > This info can be used by fan controller driver to configure PWM > source/provider accordingly. > > If you still feel that may not make sense then I'll remove this property. You evidently don't understand my comments. My suggestion is to do this: fanc: fan-controller { #pwm-cells = <3>; ... fan { pwms = <&fanc 0 500000 PWM_POLARITY_INVERTED>; ... }; }; 0 is PWM number and 500000 is the PWM frequency. The 3rd cell are per consumer flags. See pwm.txt for more details. Rob