On 09/09/2022 09:16, Astrid Rost wrote: > Hello, > > > Use standard property units "-ms". > > I made it in exactly the same way as it is done for the "ti,micbias:". > > - ti,micbias: Intended MICBIAS voltage (datasheet section 9.6.7). > Select 0/1/2/3/4/5/6/7 to specify MICBIAS voltage > 2.1V/2.2V/2.3V/2.4V/2.5V/2.6V/2.7V/2.8V > Default value is "1" (2.2V). That's not correct way. Logical units should be encoded in logical units, e.g. microvolt. This makes the binding re-usable, extendable (imagine new device from the family where these values map to something else!) and also the easiest to read. > ?> Anyway new properties cannot be accepted. This has to be converted to DT > ?> schema (YAML). > > > Doing a whole binding conversion feels like a bit of a steep requirement > > when people are just adding a simple property, it's a lot of stop energy > > to figure out the tooling, do the conversion and deal with all the > > bikeshedding that the tools don't catch. It's definitely nice if people > > want to look at that, for more complex binding changes it gets more > > reasonable but for trivial properties it's disproportionate. > > Thanks, I am not really sure how yaml works. But I can have a look. Documentation/devicetree/bindings/writing-schema.rst (and example-schema in the same place) Best regards, Krzysztof