Hi Thomas,
On 06/09/14 23:16, Thomas Petazzoni wrote:
Hello,
On Sat, 6 Sep 2014 09:06:00 -0300, Ezequiel Garcia wrote:
Confirmed. Judging from the specs, seems the same SPI IP is on all the
Armada SoCs; you can do the 'armada-spi' compatible addition on 375 and 38x.
However, I believe a compatible string like "armada-370-spi" should be
used instead of "armada-spi". The normal rule is to use the oldest SoC
that introduced a certain feature as the compatible string.
Ok, will make it that then.
Remember for example that Armada 1500 (Berlin) is a completely different
line of SoC, which cannot use this SPI driver.
Thanks Greg for working on this! I noticed this as well recently when
doing an SPI development, but you were faster than me in proposing a
patch!
No problem :-)
Regards
Greg
--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at http://vger.kernel.org/majordomo-info.html