Hello, On Sat, 6 Sep 2014 09:06:00 -0300, Ezequiel Garcia wrote: > Confirmed. Judging from the specs, seems the same SPI IP is on all the > Armada SoCs; you can do the 'armada-spi' compatible addition on 375 and 38x. However, I believe a compatible string like "armada-370-spi" should be used instead of "armada-spi". The normal rule is to use the oldest SoC that introduced a certain feature as the compatible string. Remember for example that Armada 1500 (Berlin) is a completely different line of SoC, which cannot use this SPI driver. Thanks Greg for working on this! I noticed this as well recently when doing an SPI development, but you were faster than me in proposing a patch! Thanks, Thomas -- Thomas Petazzoni, CTO, Free Electrons Embedded Linux, Kernel and Android engineering http://free-electrons.com -- To unsubscribe from this list: send the line "unsubscribe devicetree" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html