Since a HS transmission is composed of an arbitrary number of bytes that may not be an integer multiple of lanes, some lanes may run out of data before others. (Defined in 6.1.3 of mipi_DSI_specification_v.01-02-00) However, for some DSI RX devices (for example, anx7625), there is a limitation that packet number should be the same on all DSI lanes. In other words, they need to end a HS at the same time. Because this limitation is for some specific DSI RX devices, it is more reasonable to put the enable control in these DSI RX drivers. If DSI TX driver knows the information, they can adjust the setting for this situation. Signed-off-by: Jitao Shi <jitao.shi@xxxxxxxxxxxx> Signed-off-by: Rex-BC Chen <rex-bc.chen@xxxxxxxxxxxx> --- include/drm/drm_mipi_dsi.h | 2 ++ 1 file changed, 2 insertions(+) diff --git a/include/drm/drm_mipi_dsi.h b/include/drm/drm_mipi_dsi.h index 147e51b6d241..342dfe5a0874 100644 --- a/include/drm/drm_mipi_dsi.h +++ b/include/drm/drm_mipi_dsi.h @@ -137,6 +137,8 @@ struct mipi_dsi_host *of_find_mipi_dsi_host_by_node(struct device_node *node); #define MIPI_DSI_CLOCK_NON_CONTINUOUS BIT(10) /* transmit data in low power */ #define MIPI_DSI_MODE_LPM BIT(11) +/* transmit data ending in the same hsync for all lanes */ +#define MIPI_DSI_HS_PKT_END_ALIGNED BIT(12) enum mipi_dsi_pixel_format { MIPI_DSI_FMT_RGB888, -- 2.18.0