On Thu, Dec 2, 2021 at 3:06 PM Laurent Pinchart <laurent.pinchart@xxxxxxxxxxxxxxxx> wrote: > > Hi Rob, > > Thank you for the patch. > > On Wed, Dec 01, 2021 at 08:30:21PM -0600, Rob Herring wrote: > > The if/then schema for 'data-lanes' doesn't work as 'compatible' is at a > > different level than 'data-lanes'. To make it work, the if/then schema > > would have to be moved to the top level and then whole hierarchy of > > nodes down to 'data-lanes' created. I don't think it is worth the > > complexity to do that, so let's just drop it. > > Fair enough, but then shouldn't there be a comment in the data-lanes > property to tell that i.MX7 only supports up to 2 data lanes ? I'll add this to data-lanes: description: Note that 'fsl,imx7-mipi-csi2' only supports up to 2 data lines. I assume it is 1 or 2 and not only 2, right? Rob