On Mon, 31 May 2021 20:58:57 +0900, Nobuhiro Iwamatsu wrote: > Convert common clock for Xilinx Zynq MPSoC SoC bindings documentation > to YAML. > > Signed-off-by: Nobuhiro Iwamatsu <iwamatsu@xxxxxxxxxxx> > --- > .../bindings/clock/xlnx,zynqmp-clk.txt | 63 ------------------ > .../bindings/clock/xlnx,zynqmp-clk.yaml | 65 +++++++++++++++++++ > 2 files changed, 65 insertions(+), 63 deletions(-) > delete mode 100644 Documentation/devicetree/bindings/clock/xlnx,zynqmp-clk.txt > create mode 100644 Documentation/devicetree/bindings/clock/xlnx,zynqmp-clk.yaml > My bot found errors running 'make DT_CHECKER_FLAGS=-m dt_binding_check' on your patch (DT_CHECKER_FLAGS is new in v5.13): yamllint warnings/errors: dtschema/dtc warnings/errors: Documentation/devicetree/bindings/clock/xlnx,zynqmp-clk.example.dt.yaml:0:0: /example-0/firmware/zynqmp-firmware: failed to match any schema with compatible: ['xlnx,zynqmp-firmware'] See https://patchwork.ozlabs.org/patch/1485640 This check can fail if there are any dependencies. The base for a patch series is generally the most recent rc1. If you already ran 'make dt_binding_check' and didn't see the above error(s), then make sure 'yamllint' is installed and dt-schema is up to date: pip3 install dtschema --upgrade Please check and re-submit.