On Mon, Apr 12, 2021 at 03:27:38PM +0200, Clemens Gruber wrote: > The switch to the atomic API goes hand in hand with a few fixes to > previously experienced issues: > - The duty cycle is no longer lost after disable/enable (previously the > OFF registers were cleared in disable and the user was required to > call config to restore the duty cycle settings) > - If one sets a period resulting in the same prescale register value, > the sleep and write to the register is now skipped > - Previously, only the full ON bit was toggled in GPIO mode (and full > OFF cleared if set to high), which could result in both full OFF and > full ON not being set and on=0, off=0, which is not allowed according > to the datasheet > - The OFF registers were reset to 0 in probe, which could lead to the > forbidden on=0, off=0. Fixed by resetting to POR default (full OFF) I didn't recheck all details, but the patch is definitively an improvement, so: Acked-by: Uwe Kleine-König <u.kleine-koenig@xxxxxxxxxxxxxx> Best regards Uwe -- Pengutronix e.K. | Uwe Kleine-König | Industrial Linux Solutions | https://www.pengutronix.de/ |
Attachment:
signature.asc
Description: PGP signature