On Fri, Jan 8, 2021 at 6:30 PM Jonathan Neuschäfer <j.neuschaefer@xxxxxxx> wrote: > > The NPCM750 Timer/Watchdog Controller has multiple interrupt lines, > connected to multiple timers. The driver uses timer 0 for timer > interrupts, so the interrupt line corresponding to timer 0 should be > specified in DT. > > I removed the mention of "flags for falling edge", because the timer > controller uses high-level interrupts rather than falling-edge > interrupts, and whether flags should be specified is up the interrupt > controller's DT binding. > > Signed-off-by: Jonathan Neuschäfer <j.neuschaefer@xxxxxxx> Reviewed-by Avi Fishman <avifishman70@xxxxxxxxx> > --- > > v2: > - Fix a typo in the word "watchdog" > --- > .../devicetree/bindings/timer/nuvoton,npcm7xx-timer.txt | 3 +-- > 1 file changed, 1 insertion(+), 2 deletions(-) > > diff --git a/Documentation/devicetree/bindings/timer/nuvoton,npcm7xx-timer.txt b/Documentation/devicetree/bindings/timer/nuvoton,npcm7xx-timer.txt > index ea22dfe485bee..97258f1a1505b 100644 > --- a/Documentation/devicetree/bindings/timer/nuvoton,npcm7xx-timer.txt > +++ b/Documentation/devicetree/bindings/timer/nuvoton,npcm7xx-timer.txt > @@ -6,8 +6,7 @@ timer counters. > Required properties: > - compatible : "nuvoton,npcm750-timer" for Poleg NPCM750. > - reg : Offset and length of the register set for the device. > -- interrupts : Contain the timer interrupt with flags for > - falling edge. > +- interrupts : Contain the timer interrupt of timer 0. > - clocks : phandle of timer reference clock (usually a 25 MHz clock). > > Example: > -- > 2.29.2 > -- Regards, Avi