On 18/10/2020 21:30, Fabien Parent wrote:
As the binding documentation says, #mbox-cells must have a value of 2,
but the example use a value 3. The MT8173 device tree correctly use
mbox-cells = <2>. This commit fixes the example.
Signed-off-by: Fabien Parent <fparent@xxxxxxxxxxxx>
---
Fixes: 19d8e335d58a ("dt-binding: gce: remove atomic_exec in mboxes property")
With that:
Reviewed-by: Matthias Brugger <matthias.bgg@xxxxxxxxx>
Documentation/devicetree/bindings/mailbox/mtk-gce.txt | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/Documentation/devicetree/bindings/mailbox/mtk-gce.txt b/Documentation/devicetree/bindings/mailbox/mtk-gce.txt
index cf48cd806e00..7771ecaac586 100644
--- a/Documentation/devicetree/bindings/mailbox/mtk-gce.txt
+++ b/Documentation/devicetree/bindings/mailbox/mtk-gce.txt
@@ -47,7 +47,7 @@ Example:
interrupts = <GIC_SPI 135 IRQ_TYPE_LEVEL_LOW>;
clocks = <&infracfg CLK_INFRA_GCE>;
clock-names = "gce";
- #mbox-cells = <3>;
+ #mbox-cells = <2>;
};
Example for a client device: