trickle-diode-disable is deprecated, so reflect that in the driver's binding and add the new aux-voltage-chargeable. Signed-off-by: Bastian Krause <bst@xxxxxxxxxxxxxx> --- Previous version: https://lore.kernel.org/linux-rtc/20200415163701.21989-2-bst@xxxxxxxxxxxxxx/ --- Documentation/devicetree/bindings/rtc/rtc-ds1307.txt | 9 ++++++++- 1 file changed, 8 insertions(+), 1 deletion(-) diff --git a/Documentation/devicetree/bindings/rtc/rtc-ds1307.txt b/Documentation/devicetree/bindings/rtc/rtc-ds1307.txt index 66f0a31ae9ce..08ea9734da80 100644 --- a/Documentation/devicetree/bindings/rtc/rtc-ds1307.txt +++ b/Documentation/devicetree/bindings/rtc/rtc-ds1307.txt @@ -31,9 +31,16 @@ Optional properties: Selected resistor for trickle charger Possible values are 250, 2000, 4000 Should be given if trickle charger should be enabled -- trickle-diode-disable : ds1339, ds1340 and ds 1388 only +- aux-voltage-chargeable: ds1339, ds1340 and ds1388 only + Tells whether the battery/supercap of the RTC (if any) is + chargeable or not. + Possible values are 0 (not chargeable), 1 (chargeable) + +Deprecated properties: +- trickle-diode-disable : ds1339, ds1340 and ds1388 only Do not use internal trickle charger diode Should be given if internal trickle charger diode should be disabled + (superseded by aux-voltage-chargeable) Example: ds1339: rtc@68 { -- 2.28.0