The am654 SoC has three thermal zones namely MPU0, MPU1 and MCU zones Signed-off-by: Keerthy <j-keerthy@xxxxxx> --- .../dts/ti/k3-am654-industrial-thermal.dtsi | 45 +++++++++++++++++++ 1 file changed, 45 insertions(+) create mode 100644 arch/arm64/boot/dts/ti/k3-am654-industrial-thermal.dtsi diff --git a/arch/arm64/boot/dts/ti/k3-am654-industrial-thermal.dtsi b/arch/arm64/boot/dts/ti/k3-am654-industrial-thermal.dtsi new file mode 100644 index 000000000000..cdc3d40c3f60 --- /dev/null +++ b/arch/arm64/boot/dts/ti/k3-am654-industrial-thermal.dtsi @@ -0,0 +1,45 @@ +// SPDX-License-Identifier: GPL-2.0 + +#include <dt-bindings/thermal/thermal.h> + +mpu0_thermal: mpu0_thermal { + polling-delay-passive = <250>; /* milliseconds */ + polling-delay = <500>; /* milliseconds */ + thermal-sensors = <&wkup_vtm0 0>; + + trips { + mpu0_crit: mpu0_crit { + temperature = <125000>; /* milliCelsius */ + hysteresis = <2000>; /* milliCelsius */ + type = "critical"; + }; + }; +}; + +mpu1_thermal: mpu1_thermal { + polling-delay-passive = <250>; /* milliseconds */ + polling-delay = <500>; /* milliseconds */ + thermal-sensors = <&wkup_vtm0 1>; + + trips { + mpu1_crit: mpu1_crit { + temperature = <125000>; /* milliCelsius */ + hysteresis = <2000>; /* milliCelsius */ + type = "critical"; + }; + }; +}; + +mcu_thermal: mcu_thermal { + polling-delay-passive = <250>; /* milliseconds */ + polling-delay = <500>; /* milliseconds */ + thermal-sensors = <&wkup_vtm0 2>; + + trips { + mcu_crit: mcu_crit { + temperature = <125000>; /* milliCelsius */ + hysteresis = <2000>; /* milliCelsius */ + type = "critical"; + }; + }; +}; -- 2.17.1