From: Vladimir Oltean <vladimir.oltean@xxxxxxx> For debugging, it is useful to have access to the DSPI controller signals. On the reference design board, these are exported to either the mikroBUS1 or mikroBUS2 connector (according to the CPLD register BRDCFG3[SPI3]). Signed-off-by: Vladimir Oltean <vladimir.oltean@xxxxxxx> --- Changes in v5: None. Changes in v4: None. Changes in v3: None. Changes in v2: Change compatible string for spidev node. arch/arm64/boot/dts/freescale/fsl-ls1028a-rdb.dts | 14 ++++++++++++++ 1 file changed, 14 insertions(+) diff --git a/arch/arm64/boot/dts/freescale/fsl-ls1028a-rdb.dts b/arch/arm64/boot/dts/freescale/fsl-ls1028a-rdb.dts index 6d05b76c2c7a..0d27b5667b8c 100644 --- a/arch/arm64/boot/dts/freescale/fsl-ls1028a-rdb.dts +++ b/arch/arm64/boot/dts/freescale/fsl-ls1028a-rdb.dts @@ -83,6 +83,20 @@ }; }; +&dspi2 { + bus-num = <2>; + status = "okay"; + + /* mikroBUS1 */ + spidev@0 { + compatible = "rohm,dh2228fv"; + spi-max-frequency = <20000000>; + fsl,spi-cs-sck-delay = <100>; + fsl,spi-sck-cs-delay = <100>; + reg = <0>; + }; +}; + &esdhc { sd-uhs-sdr104; sd-uhs-sdr50; -- 2.17.1